Rendered vault walls after Type A waterproofing

Type A barrier protection (tanking)

020 8687 4000

When you need a barrier system

  • Vaults and small basements where space is precious
  • Soffits and walls that can take a bonded coating
  • As the first line of defence in a combined Type A and Type C design
  • Remedial work over failed systems, using RenStrength™

4.5 from 43 Google reviews

Book a survey

Clients and manufacturers

Clients

WatesRichardsons NyewoodRichardsons NyewoodMorgan Sindall ConstructionKierFaithdeanRED Construction GroupJRL GroupKnight HarwoodErithWatesRichardsons NyewoodRichardsons NyewoodMorgan Sindall ConstructionKierFaithdeanRED Construction GroupJRL GroupKnight HarwoodErithWatesRichardsons NyewoodRichardsons NyewoodMorgan Sindall ConstructionKierFaithdeanRED Construction GroupJRL GroupKnight HarwoodErithWatesRichardsons NyewoodRichardsons NyewoodMorgan Sindall ConstructionKierFaithdeanRED Construction GroupJRL GroupKnight HarwoodErith

Approved by manufacturers

MAPEIDelta Membrane SystemsKÖSTERSikaWykamolMAPEIDelta Membrane SystemsKÖSTERSikaWykamolMAPEIDelta Membrane SystemsKÖSTERSikaWykamolMAPEIDelta Membrane SystemsKÖSTERSikaWykamol
Waterproofing

How a barrier system works

A Type A system is applied directly to the structure: cementitious renders, slurries, screeds or liquid membranes, built up in coats so the finished surface holds back water.

Because there is no separate lining wall, it keeps more usable space, which matters in vaults and tight basements. The treated surfaces can often be decorated directly.

Applying a waterproof slurry to a test wall at a Köster training day
How we do it

We design it. We install it. We guarantee it.

A waterproof barrier bonded to the walls, floor and soffit that holds water back at the surface. Designed to BS 8102:2022 and installed by our own teams.

01

Preparation

Walls, floor and soffit are prepared back to a sound substrate, and active leaks are stopped first.

02

Multi-coat barrier

Waterproof slurries and renders are applied in coats to walls and soffits, with a waterproof screed to the floor.

03

Junction detailing

Wall–floor junctions and changes of substrate, such as brick to concrete, are sealed with flexible joint details.

04

Check and hand over

The finished system is checked and handed over with its documentation and guarantee.

How it works

Where the water goes

Compare the ways BS 8102 protects a basement, and where we’ve used each one.

GroundwaterGround levelDry basementWallBarrier coat

Simplified section through a basement wall. Not to scale.

Type A

Barrier protection

A waterproof render, slurry or screed is bonded to the inside of the structure and holds the water back at the surface.

Best for

  • Vaults and cellars where space matters
  • Walls that can take a bonded coating
  • Failed old tanking, using RenStrength™
On our sitesSinclair Gardens: an 18 mm multi-coat treatment kept the vaults dry with no lining wall.Read the case study
Rendered vault with a waterproofed floor
Vault walls and floor after a multi-coat Type A treatment
Featured project · Oxford

The Ashmolean Museum, Oxford University

Type A waterproofing to the 4,000 m² basement of the world’s first university museum, protecting the collections stored below ground.

“No further ingress”
“We found the Renlon team to be helpful and the operatives were diligent in ensuring that their installation was carried out to the highest standards to ensure that no further ingress ensued. I would have no hesitation in using Renlon again.”
David NottWates Construction
The Ashmolean Museum, Oxford
SystemsThree-layer Type A (Sika)
ProjectMuseum redevelopment
Read case study
Project record

Recent Type A projects

  • 1–5 London Wall2026
  • 63 New Bond Street2026
  • 20 Finsbury2025
  • Film House2025
  • Curtain House2024
  • Jubilee Plaza2024
  • 71 Regent Street2024
  • 26 King Street2024
  • 50 Hyde Park Gate2023
  • 64 St James’s Street2023
For architects and specifiers

The specification

Standards
BS 8102:2022
Manufacturers’ systems we install
  • MAPEI
  • Delta Membrane Systems
  • KÖSTER
  • Sika
  • Wykamol
Guarantee
Qualifying works carry Renlon’s own 10-year guarantee, subject to agreed terms.
Who designs and installs
Our own qualified surveyors and directly employed teams, with design responsibility backed by £10m PI cover.
FAQ

Type A Barrier Protection (Tanking): questions

Quick answers from our surveyors. Still stuck? Email survey@renlon.com and a qualified surveyor replies.

Talk to a surveyor

Reply within one business day

020 8687 4000

Mon to Fri, 8am to 4pm

Does tanking need a lining wall?

No. On our project at 33 Sinclair Gardens an 18 mm multi-coat render and slurry treatment went straight onto the vault walls and soffit, so no lining wall was needed and the surfaces could be decorated directly.

Can tanking go over old render?

Usually the old render has to come off. Our RenStrength™ system is the exception: where suitable, variation RS-2 is designed to go over existing render systems.

What is a Type A system made of?

Cementitious renders, slurries, screeds or liquid membranes, applied directly to the structure and built up in coats so the finished surface holds back water.

Can Type A be combined with Type C?

Yes. On deeper or higher-risk basements BS 8102 often calls for combined protection, and a Type A barrier is a common first line of defence alongside a Type C membrane.